MSR 385WD Multi-channel measuring system

Home » Product Range » Special (miniature) data loggers » MSR 385WD Multi-channel measuring system

MSR 385WD Multi-channel measuring system

Wireless sensor data logger up to +125 °C temperature, remote control via GSM terminal

MSR_385WD
MSR_385WD





MSR 385WD Multi-channel Measuring System: Wireless Sensor Data Logger up to +125 °C, Remote Control via LTE or LAN Terminal

MSR 385WD Multi-channel Measuring System: Recording temperature, humidity, and pressure values at various measuring points, in hard-to-reach places, between -20 °C and +125 °C, with MSR SmartCloud monitoring system: the MSR 385WD Multi-channel Measuring System data logger comes with wireless sensors that are accessible via GSM terminal

MSR 385WD Multi-channel Measuring System: Heat-resistant MSR385SM transmitter modules for long-term data recording

MSR 385WD Multi-channel Measuring System: The transmitter modules forward the data from temperature, humidity, and pressure sensors to the data logger via the ISM channel at 868 MHz frequency.
MSR 385WD Multi-channel Measuring System: Due to their heat resistance, the MSR 385SM units can operate in environments up to 125 °C, depending on the type of casing. Their compact housing allows for applications in hard-to-reach measurement locations, such as rotating machinery or museum display cases.

MSR 385WD Multi-channel Measuring System: Depending on the frequency of the measurements and radio transmission, the units can be powered for up to 10 years.

MSR385WD: Receiver Station with LTE or LAN and USB Interface

The web-based “MSR SmartCloud” enables you to store your measured data on and retrieve it from a server via the Internet. To transfer the measured data stored by the MSR385WD data logger to the MSR SmartCloud, you require the GSM terminal that is available as an optional extra.
MSR 385WD Multi-channel Measuring System: The central element of the wireless measuring system is the MSR385WD data logger, which has a memory capacity suitable for recording more than a million data points. Thanks to the integrated ISM channel module, it can store signals from up to ten MSR 385SM transmitter modules. The data logger can be recharged via USB, with a built-in 2400 mAH Li-Po battery that can operate independently without recharging. The flash memory ensures data integrity in case of power outages. The colored OLED display allows for on-site reading of the measured values from the transmitter modules.

Ideal for Remote Monitoring, Data Accessible via MSR SmartCloud

The MSR SmartCloud can be used to view the current measured values of several data loggers remotely and record them over longer periods of time.
MSR 385WD Multi-channel Measuring System: The measured and recorded data from the wireless transmitter modules can be read with the data logger. The data can be transmitted via USB for later analysis (MSR PC software). Alternatively, you can use the optional LTE/LAN terminal to access the mobile network and send the data to the MSR SmartCloud. With the MSR cloud-based service, users can store data received from the LTE/LAN terminal on a server via the Internet. This way, measurement data can not only be downloaded and analyzed from anywhere, but alerts can also be received via MSR SmartCloud if measurements exceed set limits. If needed, various data measured by different MSR units can be shared with others.

Configure Your Custom MSR385WD Data Logger

With just a few clicks, you can select and request a non-binding quote for the desired MSR285WD. If you need multiple transmitter modules with different configurations, request a custom quote for each setup. Simply provide the data logger configuration selected in point 3. Transmitter modules and data loggers can be ordered independently.

1. Choose the Temperature Range and Casing for the MSR385SM Transmitter Module

The temperature range to which the device will be exposed determines the casing that can be used. Please select the casing you need. This applies to the transmitter modules, while the data logger is specified in point 3.

Temperature
range
Enclosure and cell Image Size and weight Medium Product code
-20…+125 °C Silicone tube, replaceable
800 mAh Li-SOCl2 cell,
non-encapsulated, IP 60
For operating temperatures from -20 °C to +125 °C: MSR385SM transmitter module in silicon hose, 800 mAh Li-SOCl2 battery, not encapsulated, IP 60 35 x 25 x 55 mm
approx. 25 g
Air 385SMB63
Error
Silicone tube, replaceable
800 mAh Li-SOCl2 cell,
encapsulated, waterproof IP 67


For operating temperatures from -20 °C to +125 °C: MSR385SM transmitter module in silicon hose, 800 mAh Li-SOCl2 battery, encapsulated, IP 67 35 x 25 x 55 mm
approx. 40 g
Air, other liquids 385SMB64
Error
-20…+85 °C ABS enclosure, replaceable
3600 mAh Li-SOCl2 cell
(> 10 years
15-minute transmission interval),
external antenna,
non-encapsulated, IP 64
For operating temperatures from -20 °C to +85 °C: MSR385SM transmitter module with external aerial and 3600 mAh Li-SOCl2 battery, IP 64 60 x 33 x 80 mm
Antenna length: 93 mm
approx. 120 g
Air 385SMB66
Error
-20…+65 °C ABS enclosure, replaceable
260 mAh Li-Po battery,
non-encapsulated, IP 60
For operating temperatures from -20 °C to +65 °C: MSR385SM transmitter module in ABS housing, 260 mAh battery, not encapsulated, IP 60 38 x 15 x 78 mm
approx. 45 g
Air 385SMB65
Error

Technical data for MSR 385SM transmitter module

Frequency range: Unregistered 868 MHz (EU)
Range: Up to 500 m (open field)
LED: Red, status indicator for pressure, on/off, measurement range setting
Power supply: 260 mAh Li-Po battery (with USB charger) or replaceable 800 mAh Li-SOCl2 cell. Energy-saving operation optimizer.
Operating conditions: -20…+125 °C, in ABS case -20…+65 °C
Storage conditions:
  • +5 °C…+45 °C (ideal for battery storage).
  • 10…95% relative humidity, non-condensing environment

2. Choose sensors for the MSR385SM transmitter module.

Connect up to 3 external or internal sensors per module. We continuously expand the combination of these sensors!

Measured parameter /
Measurement/storage
Operating range /
Accuracy
Internal
sensor
External sensor (Based on cable length)
0.20 m 1.00 m 1.60 m
Temperature


1 s, 10 s, 1 min, 15 min, 1 h

-40…+125 °C
±0.2 °C (-10…+50 °C)
±1 °C (-40…+125 °C)
Item No. T5
Error
Item No. FT5/020
Error
Item No. FT5/100
Error
Item No. FT5/160
Error
Relative humidity
(with built-in temperature
sensor)


1 s, 10 s, 1 min, 15 min, 1 h

0…100 % rel. humidity
-40…+125 °C

±1.8% rel. humidity
(10…85%, 0…+40 °C)
±4% rel. humidity
(85…95%, 0…+40 °C)
Item No. H2
Error
Item No. FH2/020
Error
Item No. FH2/100
Error
Item No. FH2/160
Error
Absolute air pressure


1 s, 10 s, 1 min, 15 min, 1 h

10…1100 mbar absolute
-40…+125 °C

±2.5 mbar
(750…1100 mbar abs.,
0…+85 °C)
Item No. P6
Error
Item No. FP6/020
Error
Item No. FP6/100
Error
Item No. FP6/160
Error
10…2000 mbar absolute
-40…+85 °C

±2 mbar
(750…1100 mbar absolute,
+25 °C)
Item No. P5
Error
Item No. FP10/020
Error
Item No. FP10/100
Error
Item No. FP10/160
Error
0…14 bar absolute
-20…+85 °C

±40 mbar
(1…10 bar absolute, 0…+40 °C)
Instrument No. P7
Error
Instrument No. FP7/020
Error
Instrument No. FP7/100
Error
Instrument No. FP7/160
Error

3. Choose the MSR385WD data logger.

If you already have an MSR385WD data logger and only want to order a transmitter module, then skip this.

General technical data for the MSR385WD wireless data logger Instrument No.
MSR385WD Wireless Data Logger with integrated ISM band receiver. Receives and stores the measured data of up to ten transmitter modules (MSR385SM). A data logger operating in the 868 MHz ISM band that receives and stores measurement data. It can receive data from up to ten MSR385SM transmitter modules. Flash memory saves data in case of power outage. Display on a brilliant, high-contrast OLED (organic light-emitting diode) color screen.


Size: 75 x 25 x 120 mm with antenna
Antenna: 85 mm
Memory: More than 1 million measured values
Power supply: Lithium-polymer battery 2400 mAh (2 days operation) | USB charger
LED:
  • Blue: recording
  • Red: alarm
  • Yellow: battery status indicator
Push button: Menu functions control on the OLED display
Connector: USB, GSM terminal (EU)
PC software: Free installation, Reader, Viewer, and Online software (Windows 7/8/10) for data recording and evaluation.
Operating conditions: -20 °C to +65 °C.
Storage conditions:
  • +5…+45 °C (ideal for battery storage).
  • 10…95 % relative humidity, non-condensing environment
Certification: The MSR 385WD complies with the EU RoHS / WEEE standard.
385WDB61
Error

4. Do you need an LTE terminal to send measured data to MSR SmartCloud?

An LTE terminal will be needed if measurement data is to be sent to MSR SmartCloud via a mobile network. A LAN terminal will be needed if measurement data is to be sent to MSR SmartCloud via LAN.

Item Technical Data Item No.

LTE terminal

GSM terminal for transmitting the measured data from the MSR385WD data logger to the MSR SmartCloud.

LTE terminal, short antenna, and connector cable. The SIM card for the LTE terminal can also be ordered separately in the starter package.

LTE frequency range: B1, B3, B7, B8, B20
Dimensions: 66 x 26 x 77 mm
Weight: 80 g
Operating conditions: -30 °C…+75 °C
Power supply: via MSR385WD
N10129
Error

LTE Antenna

External magnetic antenna holder with 3 m cable.

N10121
Error

Starter Package with SIM Card
(EU Version)

  • 1 SIM card for the GSM terminal
  • Mobile data transfer, access to MSR SmartCloud for 6 months
  • Access to MSR SmartCloud for 6 months, max. 100,000 observations
N10111
Error

Extended Starter Package
(EU Version)

  • Mobile data transfer, access to MSR SmartCloud for 12 months
  • Access to MSR SmartCloud for 12 months, max. 100,000 observations
N10113
Error

 

Item Technical Data Item No.

LAN terminal

The MSR base station for automated transmission of measurement data via LAN to MSR SmartCloud.

The MSR Base Station (LAN Box) enables the automated transmission of measurement data via LAN to the MSR SmartCloud

N10110
Error

5. Using MSR SmartCloud.

The cloud solution managed by MSR Electronics GmbH stores the data recorded by MSR data loggers in a database. With online access to MSR SmartCloud, you can view your measured data, manage them, and create alert messages. When ordering the MSR385WD data logger, you will automatically receive your access code to MSR SmartCloud.

Service Description
MSR SmartCloud Free access to MSR SmartCloud when purchasing the MSR385WD data logger.
Data capacity up to 100,000 measurements, data storage for up to three months.

Selected:

Transmitter module price:
Transmitter module order number:
Data logger price:
Data logger order number:

No further information available.

Copyright © PIM Professzionális Ipari Méréstechnika Kft.
2026 | Minden jog fenntartva
Impresszum | Adatkezelés

MSR 385WD Multi-channel measuring system

Home » Product Range » Special (miniature) data loggers » MSR 385WD Multi-channel measuring system