No further information available.
Home » Product Range » Special (miniature) data loggers » MSR 385WD Multi-channel measuring system
Wireless sensor data logger up to +125 °C temperature, remote control via GSM terminal
MSR 385WD Multi-channel Measuring System: Recording temperature, humidity, and pressure values at various measuring points, in hard-to-reach places, between -20 °C and +125 °C, with MSR SmartCloud monitoring system: the MSR 385WD Multi-channel Measuring System data logger comes with wireless sensors that are accessible via GSM terminal
MSR 385WD Multi-channel Measuring System: The transmitter modules forward the data from temperature, humidity, and pressure sensors to the data logger via the ISM channel at 868 MHz frequency.
MSR 385WD Multi-channel Measuring System: Due to their heat resistance, the MSR 385SM units can operate in environments up to 125 °C, depending on the type of casing. Their compact housing allows for applications in hard-to-reach measurement locations, such as rotating machinery or museum display cases.
MSR 385WD Multi-channel Measuring System: Depending on the frequency of the measurements and radio transmission, the units can be powered for up to 10 years.

MSR 385WD Multi-channel Measuring System: The central element of the wireless measuring system is the MSR385WD data logger, which has a memory capacity suitable for recording more than a million data points. Thanks to the integrated ISM channel module, it can store signals from up to ten MSR 385SM transmitter modules. The data logger can be recharged via USB, with a built-in 2400 mAH Li-Po battery that can operate independently without recharging. The flash memory ensures data integrity in case of power outages. The colored OLED display allows for on-site reading of the measured values from the transmitter modules.

MSR 385WD Multi-channel Measuring System: The measured and recorded data from the wireless transmitter modules can be read with the data logger. The data can be transmitted via USB for later analysis (MSR PC software). Alternatively, you can use the optional LTE/LAN terminal to access the mobile network and send the data to the MSR SmartCloud. With the MSR cloud-based service, users can store data received from the LTE/LAN terminal on a server via the Internet. This way, measurement data can not only be downloaded and analyzed from anywhere, but alerts can also be received via MSR SmartCloud if measurements exceed set limits. If needed, various data measured by different MSR units can be shared with others.
With just a few clicks, you can select and request a non-binding quote for the desired MSR285WD. If you need multiple transmitter modules with different configurations, request a custom quote for each setup. Simply provide the data logger configuration selected in point 3. Transmitter modules and data loggers can be ordered independently.
The temperature range to which the device will be exposed determines the casing that can be used. Please select the casing you need. This applies to the transmitter modules, while the data logger is specified in point 3.
| Temperature range |
Enclosure and cell | Image | Size and weight | Medium | Product code |
|---|---|---|---|---|---|
| -20…+125 °C | Silicone tube, replaceable 800 mAh Li-SOCl2 cell, non-encapsulated, IP 60 |
35 x 25 x 55 mm approx. 25 g |
Air | 385SMB63 Error |
|
| Silicone tube, replaceable 800 mAh Li-SOCl2 cell, encapsulated, waterproof IP 67 |
35 x 25 x 55 mm approx. 40 g |
Air, other liquids | 385SMB64 Error |
||
| -20…+85 °C | ABS enclosure, replaceable 3600 mAh Li-SOCl2 cell (> 10 years 15-minute transmission interval), external antenna, non-encapsulated, IP 64 |
60 x 33 x 80 mm Antenna length: 93 mm approx. 120 g |
Air | 385SMB66 Error |
|
| -20…+65 °C | ABS enclosure, replaceable 260 mAh Li-Po battery, non-encapsulated, IP 60 | 38 x 15 x 78 mm approx. 45 g |
Air | 385SMB65 Error |
| Frequency range: | Unregistered 868 MHz (EU) |
| Range: | Up to 500 m (open field) |
| LED: | Red, status indicator for pressure, on/off, measurement range setting |
| Power supply: | 260 mAh Li-Po battery (with USB charger) or replaceable 800 mAh Li-SOCl2 cell. Energy-saving operation optimizer. |
| Operating conditions: | -20…+125 °C, in ABS case -20…+65 °C |
| Storage conditions: |
|
Connect up to 3 external or internal sensors per module. We continuously expand the combination of these sensors!
| Measured parameter / Measurement/storage |
Operating range / Accuracy |
Internal sensor |
External sensor (Based on cable length) | ||
|---|---|---|---|---|---|
| 0.20 m | 1.00 m | 1.60 m | |||
| Temperature
1 s, 10 s, 1 min, 15 min, 1 h |
-40…+125 °C ±0.2 °C (-10…+50 °C) ±1 °C (-40…+125 °C) |
Item No. T5 Error |
Item No. FT5/020 Error |
Item No. FT5/100 Error |
Item No. FT5/160 Error |
| Relative humidity (with built-in temperature sensor) 1 s, 10 s, 1 min, 15 min, 1 h |
0…100 % rel. humidity -40…+125 °C ±1.8% rel. humidity (10…85%, 0…+40 °C) ±4% rel. humidity (85…95%, 0…+40 °C) |
Item No. H2 Error |
Item No. FH2/020 Error |
Item No. FH2/100 Error |
Item No. FH2/160 Error |
| Absolute air pressure
1 s, 10 s, 1 min, 15 min, 1 h |
10…1100 mbar absolute -40…+125 °C ±2.5 mbar (750…1100 mbar abs., 0…+85 °C) |
Item No. P6 Error |
Item No. FP6/020 Error |
Item No. FP6/100 Error |
Item No. FP6/160 Error |
| 10…2000 mbar absolute -40…+85 °C ±2 mbar (750…1100 mbar absolute, +25 °C) |
Item No. P5 Error |
Item No. FP10/020 Error |
Item No. FP10/100 Error |
Item No. FP10/160 Error |
|
| 0…14 bar absolute -20…+85 °C ±40 mbar (1…10 bar absolute, 0…+40 °C) | Instrument No. P7 Error |
Instrument No. FP7/020 Error |
Instrument No. FP7/100 Error |
Instrument No. FP7/160 Error |
|
If you already have an MSR385WD data logger and only want to order a transmitter module, then skip this.
| General technical data for the MSR385WD wireless data logger | Instrument No. | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A data logger operating in the 868 MHz ISM band that receives and stores measurement data. It can receive data from up to ten MSR385SM transmitter modules. Flash memory saves data in case of power outage. Display on a brilliant, high-contrast OLED (organic light-emitting diode) color screen.
|
385WDB61 Error |
|||||||||||||||||||||
An LTE terminal will be needed if measurement data is to be sent to MSR SmartCloud via a mobile network. A LAN terminal will be needed if measurement data is to be sent to MSR SmartCloud via LAN.
| Item | Technical Data | Item No. | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LTE terminal
|
LTE terminal, short antenna, and connector cable. The SIM card for the LTE terminal can also be ordered separately in the starter package.
|
N10129 Error |
||||||||||
|
LTE Antenna |
External magnetic antenna holder with 3 m cable. |
N10121 Error |
||||||||||
|
Starter Package with SIM Card |
|
N10111 Error |
||||||||||
|
Extended Starter Package |
|
N10113 Error |
| Item | Technical Data | Item No. |
|---|---|---|
|
LAN terminal
|
The MSR Base Station (LAN Box) enables the automated transmission of measurement data via LAN to the MSR SmartCloud |
N10110 Error |
The cloud solution managed by MSR Electronics GmbH stores the data recorded by MSR data loggers in a database. With online access to MSR SmartCloud, you can view your measured data, manage them, and create alert messages. When ordering the MSR385WD data logger, you will automatically receive your access code to MSR SmartCloud.
| Service | Description |
|---|---|
| MSR SmartCloud | Free access to MSR SmartCloud when purchasing the MSR385WD data logger. Data capacity up to 100,000 measurements, data storage for up to three months. |
| Transmitter module order number: | |
| Data logger order number: |
No further information available.
Copyright © PIM Professzionális Ipari Méréstechnika Kft.