High-resolution spectra and very long time signals recording for two- and three-channel measurements: orbit, correlation, transient analysis envelope analysis, speed measurement resonance search functions (e.g. startup test, shutdown test) high-capacity, fast measurement-based data acquisition built-in thermal camera machine motion animation data collection impact hammer testing electric motor diagnostics
Powered by AC, DC, or internal battery, 8 to 24 - ICP powered and signal conditioned - analog channels 24-bit signal digitization, up to 1 MS/s data transfer to PC (or Laptop) 20 kHz bandwidth multi-band and real-time octave analysis tachometer input for synchronized (tracking) analysis CAN bus support, FireWire communication 24-bit DAC signal output for structural analysis quiet operation (no cooling fan) Windows-based operation and evaluation software package
32 sensor inputs (powered by the instrument) connectable: vibration acceleration and velocity sensors, eddy current displacement transducers, AC/DC process signals, 4-20 mA transmitters 4 tachometer inputs for simultaneous data recording per channel automatic alerts and information transmission (e.g. via email) built-in indicator LEDs and relays (status, alerts) can be used as standalone unit or network device Ethernet or wireless communication compact size, DIN rail mountable
professional, versatile, and highly accurate laser alignment tool 24 built-in alignment programs detailed 3D representation for machine alignment live (continuous) 3D display basic system suitable for: traditional shaft alignment 2 x 20° rotation-based shaft alignment alignment of vertical machines soft foot verification and detection thermal expansion compensation (for cold alignment) tolerance check and warning static spindle direction (spindle runout) measurement straightness, flatness, and twist measurement
for flatness and parallelism measurements
for static and dynamic bore misalignment measurements
for squareness and parallelism measurements
fanless FPA microbolometer sensor 7.5-14 μm extra-large real image resolution: 1024 x 768 pixels + micro-scan procedure 2048 x 1536 pixels (3.15 MP) fast real-time thermal image capture: 30 Hz: 1024 x 768 pixels 60 Hz: 640 x 480 pixels 120 Hz: 384 x 288 pixels 240 Hz: 128 x 96 pixels high thermal resolution: <50mK wide temperature range calibration: -40°C to 1200°C (option: > 2000°C)
compact, very easy-to-use device ultrasonic transformation into audible range indication of ultrasonic intensity with LED array equipped with a headset
structured, automatic alarm database for vibration diagnostics versatile spectrum and trend display with limit monitoring fault frequency calculation, graphical display, and textual listing expandable bearing database (with common European types) creation of highly informative automatic reports
structured, automatic alarm database for vibration diagnostics versatile spectrum and trend display with limit monitoring Proven Method - the proven machine diagnostic method of Technical Associates integration of ISO 2372, ISO 10816 vibration diagnostic standards customizable SQL/HTML reports frequency-based and partial time waveform analysis "bearing expert" with over 1 million components
structured database for storing alignment processes and machine geometry measurements versatile graphical and numerical documentation options
high-performance, versatile, 32-bit Windows software for thermography evaluations functions for storing, professional evaluating, and documenting thermal images services for detailed evaluation of thermal image sequences (e.g., creating digital videos) possibilities for post-correction of recording parameters automatic thermal image mosaic (IRBIS® 3 mosaik) versatile automatic report generation
diagnostic procedure based on modal analysis fast model creation, versatile applicability impressive results, printable graphics animations can be distributed and run with the demo program
26,000-line spectrum resolution sine, random, and impulse control up to 32,000 Hz 241 sampling settings in the 100 Hz ... 108 kHz range extremely low noise threshold (<70nV/√Hz) maximum 32 real floating-point sine with sine-random excitation <-100 dB THD+N >130 dB dynamic range redundant calibration monitor
frequency range: 5...6,500 Hz (1...9,000 Hz **) maximum vibration acceleration: 50 g max. (100 g **) sensor mass: max. 0.2 kg max. (0.5 kg **) Accuracy: < +/-2% (<+/-1% **) (** under certain calibration conditions or limitations) power amplifier: LDS PA100E
PCB 301A11 ICP reference acceleration sensor for back-to-back calibration sensitivity: 100 mV/g measurement range: ±50 g pk resolution: 0.004 g rms frequency range: (±3 dB) 0.2 Hz...20 kHz resonance frequency: ≥35 kHz spectral noise (at 1 kHz): < 15 µg/√Hz
sensor coupler/signal conditioner unit gain of 1 (non-adjustable) frequency range: 0.1 Hz...1,000 kHz spectral noise (at 1 kHz): < 0.04 µg/√Hz
4 analog channels for each ICP-type sensor (with BNC input) operation frequency range: 0.1 Hz...12,000 Hz filter type: 8th order Butterworth filtering frequency range (-3 dB): 0.2 Hz...10,600 Hz gain factor: 0 dB, 20 dB, 40 dB (1x, 10x, 100x)
Precision benchtop multimeter for industrial, service, research, and development purposes Up to 1000 measurements per second GPIB operation GPIB and RS-232 or USB interface 10 measurement functions Measurement mode: TRMS AC Digits: 1000000 VAC max.: 750 VAC VDC max.: 1000 VDC
The Workswell BB200 is a high-precision blackbody reference source for calibrating thermal cameras and infrared thermometers. Temperature range: 30°C ... 200°C (in 0.1°C steps) Temperature-stabilized surface: diameter 100 mm Emissivity in long-wave range: 0.95 ±0.005 Long-term stability: better than ±0.08%
hot-wire air velocity meter (anemometer) for measuring air velocity, volume flow, and temperature digital display (two parameters simultaneously) display of average, minimum, and maximum values
Presentable faults: Imbalance, Shaft misalignment, Tilted bearing housing, Mechanical play, loose assembly, Belt drive faults, Bent shaft, Rolling bearing faults, Gear drive faults, Electric motor frequencies
Equipment, accessories: Main shaft with shaft coupling and two discs, Auxiliary shaft unit with auxiliary shaft with brake, Belt disc set (two discs of different diameters, one good and one faulty belt), Gear set with half-side fault (two gears with different numbers of teeth), Auxiliary shaft with bad bearings, Bent auxiliary shaft (with good bearings)