No further information available.
Home » Product Range » Special (miniature) data loggers » MSR 255 Multi-channel measuring system
Robust, multifunctional data acquisition device with LCD display

With up to 5 different sensors, 4 additional analog inputs, and an LCD display, the MSR255 provides maximum flexibility and convenience.
The configuration of the MSR255 is determined by the measurement tasks set by the user: it is possible to use temperature, humidity, air pressure, and light sensors (installed inside or outside the housing via cable) as well as 3-axis acceleration sensors. Accelerations can be measured up to 3200 Hz, with approximately 50 Hz frequency digital filtering. In addition, it can measure on 4 external analog voltage measurement channels or via sensors. The analog inputs have signal output, multi-output switchable power supply, and an input for starting/stopping measurements.
The memory capacity of the MSR255 is sufficient for 2 million measurable values. Thanks to the high-capacity lithium-polymer battery, the device is suitable for long-term data acquisition applications.
The 4-line backlit LED display can be configured into 4 unique positions. The saved data can be easily and quickly accessed via USB connection on a PC or laptop.
| Housing | Technical data | Product code | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() IP 60 standard |
| 255B10 Error
| ||||||||||||||||||||||||||||||||||||||||||
![]() IP 67 waterproof | 255B11 Error
|
The MSR255 can be equipped with 5 sensors. The following external sensors can replace the internal ones: temperature, relative humidity, air pressure, and light.
| Measured parameter / Measurement/storage | Operating range / Accuracy | Internal sensor | External sensor (Based on cable length) | ||
|---|---|---|---|---|---|
| 0.20 m | 1.00 m | 1.60 m | |||
| Temperature 1/s – 12 h | external: -55…+125 °C internal: -20…+65 °C ±0.5 °C (-10…+65 °C) ±2 °C (-55…+125 °C) | T2 Error | FT2/020 Error | FT2/100 Error | FT2/160 Error |
| Relative humidity (with built-in temperature sensor) 1/s – 12 h | 0…100 % Rel. humidity external: -20…+85 °C internal: -20…+65 °C ±2 % Rel. humidity (10…85 %, 0…+40 °C) ±4 % Rel. humidity (85…95 %, 0…+40 °C) | H Error | FH/020 Error | FH/100 Error | FH/160 Error |
| Air Pressure absolute, (with built-in temperature sensing) 1/s to every 12 h | 0…2000 mbar absolute external: -20…+85 °C internal: -20…+65 °C ±2.5 mbar (750…1100 mbar absolute, +25 °C) | P Error | FP/020 Error | FP/100 Error | FP/160 Error |
| 0…14 bar absolute -20…+65 °C ±50 mbar (1…10 bar abs., +25 °C) | P2 Error | FP2/020 Error | FP2/100 Error | FP2/160 Error | |
| 3-axis Accelerometer Acceleration: 50/s (3200/s) | ±15 g -20…+65 °C ±0.15 g (0…5 g, +25 °C) ±0.25 g (5…10 g, +25 °C) ±0.45 g (10…15 g, +25 °C) | A Error | FA/020 Error | FA/100 Error | FA/160 Error |
| Light 1/s - 12 h | 0...65,000 lx max. sensitivity 500 nm | L Error | FL/020 Error | FL/100 Error | FL/160 Error |
The MSR255 can be expanded with 4 analog inputs. These inputs can be used for a wide range of external sensors. If necessary, sensors from other manufacturers can be powered from the data logger's battery. The power supply can be automatically switched on before measurements are taken, helping to account for the sensors' start-up time.
| Analog input | Input | Input configuration | Product code |
|---|---|---|---|
![]() Includes alarm output and input for starting and stopping data logging Measurement/storage speed: | 4 analog Input (Resolution: 12 Bit) | 0...3.0 V - Standard | E3333 Error |
| 4 analog Input (Resolution: 12 Bit) | Select the number of inputs for the appropriate configuration: (1) 0...20 mA | Exxxx Error |
| Device number: |
No further information available.
Copyright © PIM Professzionális Ipari Méréstechnika Kft.