Keresés

Menü

MSR 145 Multi-channel measuring system

Home » Product Range » Special (miniature) data loggers » MSR 145 Multi-channel measuring system

MSR 145 Multi-channel measuring system

Revolutionary new data logger

MSR_145
MSR_145

MSR 145 Multi-Channel Measurement System

MSR 145 Multi-Channel Measurement System: Revolutionary new data logger

The Swiss-quality, pocket-sized MSR 145 Multi-Channel Measurement System data logger assists in storing up to 2,000,000 measured values - with an additional microSD card, up to a billion values - ideal for long-term measurements. Capable of simultaneously measuring and storing temperature, humidity, air pressure, 3-axis acceleration, and light sensor data. The measured data can be quickly transferred for analysis to a PC via USB connection or through a microSD card.

MSR 145 Multi-Channel Measurement System: Versatile, universal data logger

Various types of enclosures, battery capacities, and sensors can be selected. Additionally, the MSR data logger can be equipped with analog inputs (selectable input configuration). The analog inputs allow for connecting external sensors for various measurement purposes (CO2, conductivity, pH, etc.). Furthermore, the MSR 145 Multi-Channel Measurement System comes with a free user-friendly software for data collection and analysis.

With a few clicks, you can select and request a non-binding quote for the desired MSR145.

  1. Enclosure and battery selection.
  2. Selectable sensors.
  3. Need 2 or 4 analog inputs?
  4. Want to increase the capacity of MSR145 to up to 1 billion measured values?
  5. General technical data of MSR145.

1. Enclosure and battery selection.

Enclosure Type and Battery Image Size and weight Environment Material Product code
IP 60
Standard
Ergonomic enclosure
230 mAh battery
Data logger MSR145 in design housing with 260 mAh battery, dustproof IP 60 27 x 16 x 53 mm
(W x D x H)
approx. 20 g
Air PC housing,
non-sealed
145B15
Error
Ergonomic enclosure
900 mAh battery
Data logger MSR145 in design housing with 900 mAh battery, dustproof IP 60 39 x 23 x 72 mm
(W x D x H)
approx. 56 g
Air PC housing,
non-sealed
145B7
Error
IP 67
Standard
Silicone tube
230 mAh battery
Data logger MSR145 in silicone tube with 260 mAh battery, waterproof IP 67 20 x 14 x 62 mm
(W x D x H)
approx. 18 g
Air, other
liquids
Silicone,
sealed
145B4
Error
Designed casing
230 mAh battery
Data logger MSR145 in design housing with 260 mAh battery, waterproof IP 67 27 x 16 x 53 mm
(W x D x H)
approx. 27 g
Air, other
liquids
PC casing,
sealed
145B16
Error
Designed casing
900 mAh battery
Data logger MSR145 in design housing with 900 mAh battery, waterproof IP 67 39 x 23 x 72 mm
(W x D x H)
approx. 64 g
Air, other
liquids
PC casing,
sealed
145B8
Error

2. Selectable Sensors.

Please choose your sensors for the data logger here. For temperature, humidity, and liquid pressure measurements, you can decide if you want to use multiple sensors with the same measurement parameter. Please consider the following limitations for this option:

  • Only one measured parameter can be equipped with multiple sensors.
  • The microSD card input cannot be combined with this.
  • The light sensor (L2), temperature sensor (FT), and K-type thermocouple connector (T3, T4) are not selectable.

The selected sensors are not available? Contact us for custom solutions!

Measured Parameter Operating Range Internal
Sensor
External Sensor (By Cable Length)
0.20 m 1.00 m 1.60 m
Temperature


1/s – 12 h

-10…+58 °C
±0.1 °C (+5…+45 °C)
±0.2 °C (-10…+58 °C)
External only
available
Device No. FT/020
Error
Device No. FT/100
Error
Device No. FT/160
Error
External: -55…+125 °C
Internal: -20…+65 °C

±0.5 °C (-10…+65 °C)
±2 °C (-55…+125 °C)
Device No. T2
Error
Device No. FT2/020
Error

Device No. FT2/100
Error

Device No. FT2/160
Error

Type K
thermocouple

(Without sensor)
Cannot be selected
simultaneously with
temperature sensor1/s – 12 h
1 x
-200…+1350 °C
External only
available
Device No. FT3/020
Error
Device No. FT3/100
Error
Device No. FT3/160
Error
4 x
-200…+1350 °C
External only
available
Device No. FT4/020
Error
Device No. FT4/100
Error
Device No. FT4/160
Error
Relative Humidity
(with built-in temperature
detection)1/s – 12 h
0…100 % rel. humidity
external: -20…+85 °C
internal: -20…+65 °C

±2 % rel. humidity
(10…85 %, 0…+40 °C)
±4 % rel. humidity
(85…95 %, 0…+40 °C)
Device No. H
Error
Device No. FH/020
Error

Device No. FH/100
Error

Device No. FH/160
Error

Air Pressure(absolute,
with built-in temperature
detection)10/s – 12 h
0…2000 mbar absolute
external: -20…+85 °C
internal: -20…+65 °C

±2.5 mbar
(750…1100 mbar absolute,
+25 °C)
Device No. P
Error
Device No. FP/020
Error
Device No. FP/100
Error
Item No. FP/160
Error
0…14 bar absolute
-20…+65 °C

±50 mbar
(1…10 bar abs., +25 °C)
Item No. P2
Error
Internal only available Internal only available Internal only available
Liquid Pressure
(with built-in temperature
sensor)20/s – 12 h(external sensor,
contact with transmitter
material:


  • Stainless Steel AISI 316L
    (DIN 1.4404 / 1.4435)
  • O-Rings:
    Viton® 70° Shore
0…3000 mbar absolute
-20…+85 °C

±30 mbar
External only available Item No. FP3/020
Error

Item No. FP3/100
Error

Item No. FP3/160
Error

0…30 bar absolute
-20…+85 °C

±300 mbar
External only available Item No. FP4/020
Error

Item No. FP4/100
Error

Item No. FP4/160
Error

3-axis acceleration


50/s – 12 h

±15 g
-20…+65 °C

±0.15 g (0…5 g, +25 °C)
±0.25 g (5…10 g, +25 °C)
±0.45 g (10…15 g, +25 °C)
Item No. A
Error
Item No. FA/020
Error
Item No. FA/100
Error
Item No. FA/160
Error
3-axis acceleration
(optimal max. 1kHz)
50/s – 12 h
Item No. A4
Error
Item No. FA4/020
Error
Item No. FA4/100
Error
Item No. FA4/160
Error
Light


1/s – 12 h

0…65,000 lx
max. sensitivity
500 nm
Item No. L2
Error
Item No. FL2/020
Error
Device No. FL2/100
Error
Device No. FL2/160
Error

3. Do you need 2 or 4 analog inputs?

If you want to connect external sensors from a third party to the MSR145 data logger, please indicate whether you require two or four analog inputs.

MSR145 Analog Input Input configuration Product code
Screw terminal for 4 analog inputs
Includes alarm output
and input for starting and stopping data recording
Measurement / storage frequency:
50 / s – 12 hThe following combinations are not possible:


  • Analog inputs with thermocouples
  • Analog inputs with light and temperature sensors
2 Analog input
(Resolution: 12 Bit)
0…3.0 V – Standard E33
Error
4 Analog input
(Resolution: 12 Bit)
0…3.0 V – Standard E3333
Error
2 Analog input
(Resolution: 12 Bit)
Select the number of inputs
for the appropriate configuration:
(1)


0…20 mA

(2)


4…20 mA

(3)


0…3.0 V

(4)


0.5…4.5 V / 0…5.0 V

(5)


0…10.0 V / 1.0…6.0 V

(6)


0…12.0 V

(7)


0…24.0 V
Exx
Error
4 Analog Input
(Resolution: 12 Bit)
Exxxx
Error

4. Would you like to increase the capacity of the MSR 145 Multichannel Data Logger up to 1 billion measured values?

Please order the connector for the standard microSD card here. Product Code
Slot for microSD card (Only for B7 and B8 enclosures)Please note that:


  • With this microSD card accessory, the B8 enclosure only complies with the IP60 standard.
  • Not compatible with temperature sensors and light sensors.
  • The accessory cannot be combined with devices equipped with multiple identical sensors.
  • The package includes a pre-formatted microSD card ready for immediate use (≥4GB).
N10006
Error

5. General Technical Data of MSR 145 Multichannel Data Logger.

Memory: More than 2 million measured values – expandable up to 1 billion values with microSD card
Push Button: Bookmark setting, start/stop function
LED Display:
blue:
red:
yellow:
recording
alert
battery status indicator
Power Supply:
  • Lithium-polymer battery
  • 260 mAh or 900 mAh
  • USB charger
Selectable: Charging station (USB hub) for 7 MSR145
Connector: USB
PC software: Free installer, Reader, Viewer, and Online software (Windows XP/Vista/7/8/10) for data recording and evaluation. The measured data can be accessed from a PC via USB connection, even during measurement.
Thanks to the internal integrated real-time clock (RTC), data extracted from individual MSR 145 units can be synchronized and aggregated as needed.
Operating conditions:
-20…+65 °C
Storage conditions:
+5…+45 °C (ideal for battery storage)
10…95% relative humidity, condensation-free environment
Certification: The MSR 145 complies with the EU RoHS / WEEE standards.