MSR 145 Multi-Channel Measurement System

The Swiss-quality, pocket-sized MSR 145 Multi-Channel Measurement System data logger assists in storing up to 2,000,000 measured values - with an additional microSD card, up to a billion values - ideal for long-term measurements. Capable of simultaneously measuring and storing temperature, humidity, air pressure, 3-axis acceleration, and light sensor data. The measured data can be quickly transferred for analysis to a PC via USB connection or through a microSD card.
Various types of enclosures, battery capacities, and sensors can be selected. Additionally, the MSR data logger can be equipped with analog inputs (selectable input configuration). The analog inputs allow for connecting external sensors for various measurement purposes (CO2, conductivity, pH, etc.). Furthermore, the MSR 145 Multi-Channel Measurement System comes with a free user-friendly software for data collection and analysis.
With a few clicks, you can select and request a non-binding quote for the desired MSR145.
| Enclosure | Type and Battery | Image | Size and weight | Environment | Material | Product code |
|---|---|---|---|---|---|---|
| IP 60 Standard |
Ergonomic enclosure 230 mAh battery |
27 x 16 x 53 mm (W x D x H) approx. 20 g |
Air | PC housing, non-sealed |
145B15 Error |
|
| Ergonomic enclosure 900 mAh battery |
39 x 23 x 72 mm (W x D x H) approx. 56 g |
Air | PC housing, non-sealed |
145B7 Error |
||
| IP 67 Standard | Silicone tube 230 mAh battery |
20 x 14 x 62 mm (W x D x H) approx. 18 g |
Air, other liquids |
Silicone, sealed |
145B4 Error |
|
| Designed casing 230 mAh battery |
27 x 16 x 53 mm (W x D x H) approx. 27 g |
Air, other liquids |
PC casing, sealed |
145B16 Error |
||
| Designed casing 900 mAh battery |
39 x 23 x 72 mm (W x D x H) approx. 64 g |
Air, other liquids |
PC casing, sealed |
145B8 Error |
Please choose your sensors for the data logger here. For temperature, humidity, and liquid pressure measurements, you can decide if you want to use multiple sensors with the same measurement parameter. Please consider the following limitations for this option:
The selected sensors are not available? Contact us for custom solutions!
| Measured Parameter | Operating Range | Internal Sensor |
External Sensor (By Cable Length) | ||
|---|---|---|---|---|---|
| 0.20 m | 1.00 m | 1.60 m | |||
| Temperature
1/s – 12 h |
-10…+58 °C ±0.1 °C (+5…+45 °C) ±0.2 °C (-10…+58 °C) |
External only available |
Device No. FT/020 Error |
Device No. FT/100 Error |
Device No. FT/160 Error |
| External: -55…+125 °C Internal: -20…+65 °C ±0.5 °C (-10…+65 °C) ±2 °C (-55…+125 °C) |
Device No. T2 Error |
Device No. FT2/020 Error |
Device No. FT2/100 Error |
Device No. FT2/160 Error |
|
| Type K thermocouple (Without sensor) Cannot be selected simultaneously with temperature sensor1/s – 12 h |
1 x -200…+1350 °C |
External only available |
Device No. FT3/020 Error |
Device No. FT3/100 Error |
Device No. FT3/160 Error |
| 4 x -200…+1350 °C |
External only available |
Device No. FT4/020 Error |
Device No. FT4/100 Error |
Device No. FT4/160 Error |
|
| Relative Humidity (with built-in temperature detection)1/s – 12 h |
0…100 % rel. humidity external: -20…+85 °C internal: -20…+65 °C ±2 % rel. humidity (10…85 %, 0…+40 °C) ±4 % rel. humidity (85…95 %, 0…+40 °C) |
Device No. H Error |
Device No. FH/020 Error |
Device No. FH/100 Error |
Device No. FH/160 Error |
| Air Pressure(absolute, with built-in temperature detection)10/s – 12 h |
0…2000 mbar absolute external: -20…+85 °C internal: -20…+65 °C ±2.5 mbar (750…1100 mbar absolute, +25 °C) |
Device No. P Error |
Device No. FP/020 Error |
Device No. FP/100 Error |
Item No. FP/160 Error |
| 0…14 bar absolute -20…+65 °C ±50 mbar (1…10 bar abs., +25 °C) |
Item No. P2 Error |
Internal only available | Internal only available | Internal only available | |
| Liquid Pressure (with built-in temperature sensor)20/s – 12 h(external sensor, contact with transmitter material:
|
0…3000 mbar absolute -20…+85 °C ±30 mbar |
External only available | Item No. FP3/020 Error |
Item No. FP3/100 Error |
Item No. FP3/160 Error |
| 0…30 bar absolute -20…+85 °C ±300 mbar |
External only available | Item No. FP4/020 Error |
Item No. FP4/100 Error |
Item No. FP4/160 Error |
|
| 3-axis acceleration
50/s – 12 h |
±15 g -20…+65 °C ±0.15 g (0…5 g, +25 °C) ±0.25 g (5…10 g, +25 °C) ±0.45 g (10…15 g, +25 °C) |
Item No. A Error |
Item No. FA/020 Error |
Item No. FA/100 Error |
Item No. FA/160 Error |
| 3-axis acceleration (optimal max. 1kHz)50/s – 12 h |
Item No. A4 Error |
Item No. FA4/020 Error |
Item No. FA4/100 Error |
Item No. FA4/160 Error |
|
| Light
1/s – 12 h |
0…65,000 lx max. sensitivity 500 nm |
Item No. L2 Error |
Item No. FL2/020 Error |
Device No. FL2/100 Error |
Device No. FL2/160 Error |
If you want to connect external sensors from a third party to the MSR145 data logger, please indicate whether you require two or four analog inputs.
| MSR145 Analog | Input | Input configuration | Product code |
|---|---|---|---|
![]() Includes alarm output and input for starting and stopping data recording Measurement / storage frequency: 50 / s – 12 hThe following combinations are not possible:
|
2 Analog input (Resolution: 12 Bit) |
0…3.0 V – Standard | E33 Error |
| 4 Analog input (Resolution: 12 Bit) |
0…3.0 V – Standard | E3333 Error |
|
| 2 Analog input (Resolution: 12 Bit) |
Select the number of inputs for the appropriate configuration: (1) 0…20 mA (2) 4…20 mA (3) 0…3.0 V (4) 0.5…4.5 V / 0…5.0 V (5) 0…10.0 V / 1.0…6.0 V (6) 0…12.0 V (7) 0…24.0 V |
Exx Error |
|
| 4 Analog Input (Resolution: 12 Bit) |
Exxxx Error |
| Please order the connector for the standard microSD card here. | Product Code |
|---|---|
Slot for microSD card (Only for B7 and B8 enclosures)Please note that:
|
N10006 Error |
| Memory: | More than 2 million measured values – expandable up to 1 billion values with microSD card | |
| Push Button: | Bookmark setting, start/stop function | |
| LED Display: | ||
| blue: red: yellow: |
recording alert battery status indicator |
|
| Power Supply: |
|
|
| Selectable: | Charging station (USB hub) for 7 MSR145 | |
| Connector: | USB | |
| PC software: | Free installer, Reader, Viewer, and Online software (Windows XP/Vista/7/8/10) for data recording and evaluation. The measured data can be accessed from a PC via USB connection, even during measurement. Thanks to the internal integrated real-time clock (RTC), data extracted from individual MSR 145 units can be synchronized and aggregated as needed. |
|
| Operating conditions: | ||
| -20…+65 °C | ||
| Storage conditions: | ||
| +5…+45 °C (ideal for battery storage) 10…95% relative humidity, condensation-free environment |
||
| Certification: | The MSR 145 complies with the EU RoHS / WEEE standards. | |